Moving Iron Instruments |
|
|
Ammeters and Voltmeters for AC applications |
|
Sizes |
48mm Sq. |
72mm Sq. |
96mm Sq. |
144mm Sq. |
110mm Round Flush |
100X80mm |
Accuracy |
2.5 |
1.5 |
1.5 |
1.0 |
1.0 |
2.0 |
|
|
Ranges: |
a) Ammeter: 0-0. 1A to 0-100A* b) Voltmeter: 0-15V to 0-600V. |
Note: |
CT operated Ammeters with basic 5A or 1A are available for higher ranges.
PT operated Voltmeters with secondary 110V are available for higher ranges. |
*Max. Current rating for 48mm Sq. Meter is 0-15A only and 100X80 mm is 30A only. |
Suppressed Scale Ammeter with 6 Times Basic Current is available. |
|
|
|
Moving Coil Instruments |
|
|
|
Ammeters and Voltmeters for DC applications |
|
Sizes |
48mm Sq. |
72mm Sq. |
96mm Sq. |
144mm Sq. |
110mm Round Flush |
100X80mm |
Accuracy |
2.5 |
1.5 |
1.5 |
1.0 |
1.0 |
2.0 |
|
|
Ranges: |
a) Ammeter: 0-50 µA to 0-30A* b) Voltmeter: 0-50mV to 0-600V. |
Note: |
Shunt operated Ammeter with 75mV drop available for current above 30A. External series resistances are provided for voltage above 600V. |
*Max. Current rating for 48mm Sq. Meter is 0-10A only |
|
|
|
Moving Coil Instruments with Rectifier |
|
|
Ammeters and Voltmeters for AC applications |
|
Sizes |
48mm Sq. |
72mm Sq. |
96mm Sq. |
144mm Sq. |
110mm Round Flush |
100X80mm |
Accuracy |
2.5 |
1.5 |
1.5 |
1.0 |
1.0 |
2.0 |
|
|
Ranges: |
a) Ammeter: 0-100µA to 0-30A* b) Voltmeter: 0-5mV to 0-600V. |
Note: |
CT operated Ammeters with basic 5A or 1A are available for higher ranges.
PT operated Voltmeters with secondary 110V are available for higher ranges. |
External transducer for Ammeter above 0-0.5A for 48mm and 72mm Sq. meter |
|
|
|
Moving Coil Instruments with Suppressed Zero |
|
|
Sizes |
48mm Sq. |
72mm Sq. |
96mm Sq. |
144mm Sq. |
110mm Round Flush |
100X80mm |
Accuracy |
2.5 |
1.5 |
1.5 |
1.0 |
1.0 |
2.0 |
|
|
Ranges: |
0-100/120V, 0-180/240V, 0-360/440V. |
|
|
|
Frequency Meters |
|
|
Pointer type |
|
Sizes |
48mm Sq. |
72mm Sq. |
96mm Sq. |
144mm Sq. |
Accuracy |
1.0 |
1.0 |
1 |
1 |
|
|
Voltage: |
110V or 230V or 440V (±10%) |
Frequency: |
45-55Hz, 45-65Hz, 55-65Hz, 47-53Hz,57-63Hz, 360-440Hz, |
External transducer for 48mm Sq. Meter. |
|
|
|
|
Reeds Type |
|
Sizes |
72mm Sq. |
96mm Sq. |
144mm Sq. |
Accuracy |
1.0 |
1.0 |
1.0 |
|
|
Voltage: |
110V or 230V or 440V (±10%) |
Frequency: |
45-55Hz, 47-53Hz, 55-65Hz, 57-63Hz. |
|
|
|
Power Meters |
|
Moving Coil Type |
|
|
Wattmeters with external transducer for single phase |
|
Sizes |
72mm Sq. |
96mm Sq. |
144mm Sq. |
Accuracy Class |
1.5 |
1.5 |
1 |
|
|
Voltage: |
110V or 230V or 440V Current: …./1A or …./5A |
CT & PT may be used for higher Ranges |
|
|
|
|
Wattmeters and Varmeters with external/internal transducer* For 3 phase 3 wire or 4 wire (Balanced and Unbalanced load) |
|
Sizes |
72mm Sq. |
96mm Sq. |
144mm Sq. |
Accuracy Class |
1.5 |
1.5 |
1.5 |
|
|
Voltage: |
110V or 230V or 440V Current: …./1A or …./5A |
CT & PT may be used for higher Ranges |
|
|
|
|
Power Factor Meter with external/internal transducer*
For single phase and for 3 phase 3 wire or 4 wire (Balanced load) |
|
Sizes |
72mm Sq. |
96mm Sq. |
144mm Sq. |
Accuracy |
2.5 |
2.5 |
2.5 |
|
|
Voltage: |
110V or 230V or 440V Current: …./1A or …./5A |
Cos: |
Lag 0.5-1-0.5 lead or lag 0.3-1-0.7lead or 0.4-1-0.4 lead |
CT & PT may be used for Higher Ranges |
*90 & 240 scale available. |
|
|
|
Electrodynamo Type |
|
|
Wattmeter, Varmeter and KVA Meter for single Phase And 3 phase 3 wires or 4 wire (Balanced and Unbalanced load) |
|
Sizes |
96mm Sq. |
144mm Sq. |
Accuracy |
1.5 |
1.5 |
|
|
Voltage: |
110V or 230V or 440V Current: …./1A or …./5A |
Cos: |
Lag 0.5-1-0.5 lead or lag 0.3-1-0.7lead or 0.4-1-0.4 lead |
CT & PT may be used for Higher Ranges |
|
|
|
|
Power Factor Meter for Single Phase and 3 phase 3 wire or 4 wire (Balanced and Unbalanced load) |
|
Sizes |
96mm Sq. |
144mm Sq. |
Accuracy |
2.5 |
2.5 |
|
|
Voltage: |
110V or 230V or 440V Current: …./1A or …./5A |
Cos: |
Lag 0.5-1-0.5 lead |
CT & PT may be used for Higher Ranges |
|
|
|
Sychronising Meters |
|
Meter |
Double Voltmeter |
Double Frequency Meter |
Synchronoscope |
Sizes |
144mm Sq. |
144mm Sq. |
144mm Sq. |
Range |
110V or 440V |
110V or 440V |
110V or 440V |
Accuracy |
1.0 |
1.0 |
– |
|
|
|
|
|
|
|